You have solar panels on your roof. The power goes out. Does your solar keep working? The answer depends entirely on your system type.
This surprises most people. A grid-tied solar system — panels connected to a grid-tie inverter with no battery — stops generating power the moment the grid goes down. Your panels are producing electricity, the sun is shining, and your house is dark. This isn't a malfunction. It's a safety feature called anti-islanding protection.
When the grid goes down, linemen work on the power lines to fix the fault. If your solar system keeps pushing electricity into the grid, those "dead" power lines become energised — potentially at lethal voltages. A lineman touching a wire they believe is de-energised could be electrocuted by your solar system's output.
Anti-islanding is mandatory for all grid-connected inverters worldwide (IEC 62116, IEEE 1547, India's CEA Technical Standards for Connectivity). The inverter continuously monitors grid voltage and frequency. If grid voltage drops to zero (outage) or drifts outside the acceptable range (47.5–51.5 Hz, 180–270 V for single phase), the inverter disconnects within 2 seconds and stops converting DC to AC. It remains off until the grid is restored and stable for 5 minutes (the reconnect timer).
A hybrid solar system has a battery and an inverter/charger that can operate in both grid-connected and standalone (island) modes. When the grid goes down:
The transfer from grid to battery takes 10–20 milliseconds for quality inverters. This is fast enough that most electronics (computers, routers, TVs) don't notice the switch. Clocks don't reset. WiFi doesn't drop. The only appliances that might notice are motor-driven loads in the middle of a start cycle.
| System Type | Power During Grid Outage | Backup Duration | Transfer Time |
|---|---|---|---|
| Grid-tied (no battery) | None — complete shutdown | 0 hours | N/A |
| Grid-tied + basic UPS | UPS loads only (computer, router) | 15–30 minutes | 5–10 ms (offline UPS) |
| Hybrid (solar + battery) | All loads up to inverter capacity | 4–24 hours (depends on battery) | 10–20 ms |
| Off-grid (solar + battery) | All loads — no grid dependency | 12–48+ hours | 0 ms (always on battery) |
Backup duration depends on three variables: battery capacity, load, and whether the sun is shining.
Nighttime outage (no solar generation):
| Battery Capacity | Light Load (500 W avg) | Medium Load (1.5 kW avg) | Heavy Load (3 kW avg) |
|---|---|---|---|
| 5 kWh LFP | 8.5 hours | 2.8 hours | 1.4 hours |
| 10 kWh LFP | 17 hours | 5.7 hours | 2.8 hours |
| 15 kWh LFP | 25.5 hours | 8.5 hours | 4.3 hours |
| 20 kWh LFP | 34 hours | 11.3 hours | 5.7 hours |
Assumes 85% DoD for LFP and 92% inverter efficiency.
Daytime outage (solar generating): If solar generation exceeds the load, the battery charges while powering your home — backup is essentially unlimited until sunset. If solar generation is less than the load (cloudy day), the battery supplements the shortfall and backup duration extends proportionally.
Alloy Charge hybrid systems provide seamless transition. The FreedomVolt inverter detects grid failure in under 20 ms and transitions to battery power without disrupting connected loads. During a daytime outage, the SunXtractor continues charging the PowerVault battery from solar panels while simultaneously powering your home — the system operates as a self-contained microgrid until the grid returns. Load prioritisation ensures critical loads (lights, fridge, WiFi) are served first, and non-essential loads (AC, water heater) are shed when battery falls below configurable thresholds.
A well-designed hybrid system doesn't just provide backup — it manages backup intelligently. The priority stack:
This can be implemented through separate circuits on the distribution board — critical loads on the inverter-backed circuit, deferrable loads on a grid-only circuit that loses power during outages. Or through smart energy management that controls individual loads based on battery state-of-charge.
| Location Type | Annual Outage Hours (avg) | Typical Outage Duration | Main Causes |
|---|---|---|---|
| Bangalore urban (BESCOM) | 30–60 hours | 30 min – 2 hours | Planned maintenance, tree falls, equipment failure |
| Bangalore suburban | 60–120 hours | 1–4 hours | Transformer overload, cable faults, monsoon damage |
| Semi-urban Karnataka | 120–300 hours | 2–8 hours | Load shedding, infrastructure age, weather |
| Rural Karnataka | 300–1,000+ hours | 4–12 hours | Scheduled load shedding, single feeder, limited maintenance |
| Remote/agricultural | 1,000–3,000+ hours | 6–18 hours | Agricultural supply timing, infrastructure absence |
Urban Bangalore consumers experience 30–60 hours of outages per year — roughly an hour per week. Rural consumers can face 3–8 hours daily. For rural and semi-urban properties, battery backup isn't a luxury — it's the difference between functional living and regular disruption.
If you already have a grid-tied system without battery and want backup capability, you have two paths:
A battery-backed solar system keeps your home running during outages — automatically, silently, and without a DG set.
Add Battery Backup to Your System